Missing flush information in Orcaslicer? #54

Closed
opened 2026-06-13 00:03:07 +02:00 by omega235 · 1 comment

I’m not sure if I’ve set up OrcaSlicer incorrectly or if there is missing functionality.

In AnycubicSlicer, I can see all the details regarding flushing (time, amount).

Also, the print time estimate in AnycubicSlicer is very accurate (±5 minutes for a 2-hour print). OrcaSlicer is way off (up to 40 minutes for a 2-hour print). The more color changes there are, the more extreme the discrepancy becomes.

AnycubicSlicer:
grafik.png
OrcaSlicer:
grafik.png

Orca-Slicer:
2.4.0-alpha-kx2 (0f4c6dffff) und 2.4.0-dev nightbuild (fc9a8aa9)
AnycubicSlicer:
1.4.1.2

I’m not sure if I’ve set up OrcaSlicer incorrectly or if there is missing functionality. In AnycubicSlicer, I can see all the details regarding flushing (time, amount). Also, the print time estimate in AnycubicSlicer is very accurate (±5 minutes for a 2-hour print). OrcaSlicer is way off (up to 40 minutes for a 2-hour print). The more color changes there are, the more extreme the discrepancy becomes. AnycubicSlicer: ![grafik.png](/attachments/bd9970a7-2219-4f5c-8b0f-2eeefe0a1ffe) OrcaSlicer: ![grafik.png](/attachments/bb365699-9483-448e-9e6c-0b70052bc8fd) Orca-Slicer: 2.4.0-alpha-kx2 (0f4c6dffff) und 2.4.0-dev nightbuild (fc9a8aa9) AnycubicSlicer: 1.4.1.2
Owner

Thanks for the report.

The time discrepancy comes down to OrcaSlicer not knowing the actual filament-change (flush/purge) times of the Kobra X ACE. Anycubic Slicer has these values hardcoded for its own hardware and can therefore calculate a much more accurate estimate. OrcaSlicer uses its own generic defaults which do not match the real ACE cycle times.

This is a known limitation — we have noted it as a future improvement (adding accurate ACE flush/change times to the OrcaSlicer-KX machine profile). No ETA yet, but it is on our list.

Thanks for the report. The time discrepancy comes down to OrcaSlicer not knowing the actual filament-change (flush/purge) times of the Kobra X ACE. Anycubic Slicer has these values hardcoded for its own hardware and can therefore calculate a much more accurate estimate. OrcaSlicer uses its own generic defaults which do not match the real ACE cycle times. This is a known limitation — we have noted it as a future improvement (adding accurate ACE flush/change times to the OrcaSlicer-KX machine profile). No ETA yet, but it is on our list.