FIX: fix flow ratio calib bug for single extruder printer
2. modify the filament_flow_ratio to nullable jira:none Change-Id: I3f0569ee643cfe9473c6029ca0e04f4b80c8332e (cherry picked from commit ed61d1d31bdc79f064567deacf35e05bd123880d)
This commit is contained in:
@@ -514,9 +514,8 @@ int CalibrationPresetPage::get_extruder_id(int ams_id)
|
||||
if (m_ams_id_to_extruder_id_map.find(ams_id) != m_ams_id_to_extruder_id_map.end()) {
|
||||
return m_ams_id_to_extruder_id_map[ams_id];
|
||||
}
|
||||
else {
|
||||
return -1;
|
||||
}
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
void CalibrationPresetPage::create_selection_panel(wxWindow* parent)
|
||||
@@ -662,7 +661,7 @@ void CalibrationPresetPage::init_selection_values()
|
||||
}
|
||||
|
||||
for (size_t i = 0; i < m_comboBox_nozzle_volume_types.size(); ++i) {
|
||||
m_comboBox_nozzle_volume_types[i]->SetSelection(int(NozzleVolumeType::nvtBigTraffic));
|
||||
m_comboBox_nozzle_volume_types[i]->SetSelection(int(NozzleVolumeType::nvtNormal)); // default for single extruder printer
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -1176,7 +1175,7 @@ void CalibrationPresetPage::on_recommend_input_value()
|
||||
else if (m_cali_mode == CalibMode::Calib_Flow_Rate && m_cali_stage_panel) {
|
||||
Preset *selected_filament_preset = selected_filaments.begin()->second;
|
||||
if (selected_filament_preset) {
|
||||
const ConfigOptionFloats* flow_ratio_opt = selected_filament_preset->config.option<ConfigOptionFloats>("filament_flow_ratio");
|
||||
const ConfigOptionFloatsNullable* flow_ratio_opt = selected_filament_preset->config.option<ConfigOptionFloatsNullable>("filament_flow_ratio");
|
||||
if (flow_ratio_opt) {
|
||||
m_cali_stage_panel->set_flow_ratio_value(flow_ratio_opt->get_at(0));
|
||||
}
|
||||
@@ -2011,7 +2010,6 @@ void CalibrationPresetPage::sync_ams_info(MachineObject* obj)
|
||||
info.parse_ext_info(obj, vt_tray);
|
||||
info.ams_type = AMSModel::EXT_AMS;
|
||||
|
||||
assert(m_main_ams_preview_list.size() == 4);
|
||||
AMSPreview *vt_item = m_main_ams_preview_list[4];
|
||||
vt_item->Update(info);
|
||||
vt_item->Open();
|
||||
@@ -2021,7 +2019,6 @@ void CalibrationPresetPage::sync_ams_info(MachineObject* obj)
|
||||
info.parse_ext_info(obj, vt_tray);
|
||||
info.ams_type = AMSModel::EXT_AMS;
|
||||
|
||||
assert(m_deputy_ams_preview_list.size() == 4);
|
||||
AMSPreview *vt_item = m_deputy_ams_preview_list[4];
|
||||
vt_item->Update(info);
|
||||
vt_item->Open();
|
||||
@@ -2203,7 +2200,7 @@ void CalibrationPresetPage::get_cali_stage(CaliPresetStage& stage, float& value)
|
||||
if (stage != CaliPresetStage::CALI_MANUAL_STAGE_2) {
|
||||
std::map<int, Preset*> selected_filaments = get_selected_filaments();
|
||||
if (!selected_filaments.empty()) {
|
||||
const ConfigOptionFloats* flow_ratio_opt = selected_filaments.begin()->second->config.option<ConfigOptionFloats>("filament_flow_ratio");
|
||||
const ConfigOptionFloatsNullable* flow_ratio_opt = selected_filaments.begin()->second->config.option<ConfigOptionFloatsNullable>("filament_flow_ratio");
|
||||
if (flow_ratio_opt) {
|
||||
m_cali_stage_panel->set_flow_ratio_value(flow_ratio_opt->get_at(0));
|
||||
value = flow_ratio_opt->get_at(0);
|
||||
|
||||
Reference in New Issue