1) Slic3r::RuntimeError was replaced with ConfigurationError,
all exceptions thrown by the configuration layer are derived
from ConfigurationError.
2) When parsing configuration files, ConfigurationError is catched and
rethrown extended with the file name being parsed.
Note: When ProgressDialog has no-nullptr parent, then PrusaSlicer doesn't lose the focus at the end of model fixing,
but start to flickering during fixing of the big models.
Make is_converted_from_meters / is_converted_from_inches exclusive-or.
Maybe it would be better to make a single enum from the two booleans,
if they are exclusive-or?
This reverts commit d001195ebd. It makes no sense,
reload from disk is used when the file has changed, which means the paint-on
data are possibly meaningless or even completely wrong (referencing
triangles that no longer exist)
when the respective object info line was clicked, the variable
layer height mode was opened correctly, but closing it through
the toolbar deactivated most of the icons as if it was just opened.
+ ProjectDropDialog: wxRadiloBox was changes to the wxStaticBox with wxRadioButtons because of dark mode colors update
+ Preferences: Fixed update of the text colors
* MSW specific: First implementation of the Notebook control to support Dark/Light color modes
* MSW specific: Set mode sizer to the Notebook control.
* MSW specific: Added icons to the Notepad control
+ There is no need to restart application after the changing of the color mode
* Fixed non-MSW build
* Updated color for SavePresetDialog
+ Added wrapper to wxMessageBox for mom-MSW platforms
sets of optional boolean parameters, the cut function "keep upper",
"keep lower" and "flip lower" boolean parameters were converted into
a single type safe enum_bitmask. Such a coding style is certainly
wordier than the original code, but much safer and more readable
than the error prone "boolean, boolean, boolean" function call
parameter list.
config bundles, project files (3MFs, AMFs). When loading these files,
the caller may decide whether to substitute some of the configuration
values the current PrusaSlicer version does not understand with
some reasonable default value, and whether to report it. If substitution
is disabled, an exception is being thrown as before this commit.
If substitution is enabled, list of substitutions is returned by the
API to be presented to the user. This allows us to introduce for example
new firmware flavor key in PrusaSlicer 2.4 while letting PrusaSlicer
2.3.2 to fall back to some default and to report it to the user.
When slicing from command line, substutions are performed by default
and reported into the console, however substitutions may be either
disabled or made silent with the new "config-compatibility" command
line option.
Substitute enums and bools only. Allow booleans to be parsed as
true: "1", "enabled", "on" case insensitive
false: "0", "disabled", "off" case insensitive
This will allow us in the future for example to switch the draft_shield
boolean to an enum with the following values: "disabled" / "enabled" / "limited".
Added "enum_bitmask.hpp" - support for type safe sets of options.
See for example PresetBundle::load_configbundle(...
LoadConfigBundleAttributes flags) for an example of intended usage.
WIP: GUI for reporting the list of config substitutions needs to be
implemented by @YuSanka.