Remove redundant toolchange retraction/un-retraction during filament change in CC1 profile (#13456)
* Fix: Disable redundant toolchange retraction for Elegoo Centauri Carbon Sets `retract_length_toolchange` to 0 in the Elegoo Centauri Carbon (ECC) machine profile. This resolves an issue where a massive filament blob would form on the prime tower immediately after resuming a manual filament change (M600). The blob was caused by a conflict between OrcaSlicer's default toolchange logic and Elegoo's hardcoded firmware behavior: - Elegoo's firmware (specifically the `cmd_PAUSE` and `cmd_RESUME` sequences) completely takes over pressure management during an M600. It performs its own initial 2mm retraction, a 120mm purge, and a silicone brush wipe, returning the print head to the prime tower perfectly primed. - Previously, Slicer was unaware of the firmware's priming and would issue a redundant 2mm un-retract (`G1 E2`) upon resume. Forcing 2mm of filament out of an already-full nozzle created the blob. By disabling the toolchange retraction (`0`), Slicer correctly hands off filament pressure management during an M600 entirely to the Elegoo firmware, preventing double-retractions and eliminating the blob. * fix errors after merging main --------- Co-authored-by: SoftFever <softfeverever@gmail.com>
This commit is contained in:
@@ -48,6 +48,9 @@
|
||||
"extruder_offset": [
|
||||
"0x0"
|
||||
],
|
||||
"retract_length_toolchange": [
|
||||
"0"
|
||||
],
|
||||
"default_bed_type": "4",
|
||||
"auto_toolchange_command": "0",
|
||||
"fan_speedup_time": "0.5",
|
||||
|
||||
Reference in New Issue
Block a user